More Helpful Information about 5-2-1 Compressor Savers and Other HVAC Enhancement Options

A 5-2-1 Compressor Saver® significantly reduces the amount of time your AC compressor takes to start. Air conditioners with the 5-2-1 Compressor Saver® typically start in 30-50% less time than air conditioners without the product.

This is important because the compressor on your air conditioner consumes more power on start-up than any other device in your home. Start-up is the hardest time in the life of any type of insulation equipment. Ever noticed that light bulbs almost always burn out when you first turn them on and not while they are on? This is due to the huge current that rushes in when a switch is thrown and power is first applied. 

An AC compressor may consume 45,000 watts of power while the motor is trying to start and that's ten times more power than it uses while running. By comparison, the large burner on an electric stove only consumes approximately 5,000 watts on high. The heat that accompanies the in-rush current can damage vital insulation components, including your air conditioner compressor, the air conditioner-run capacitor, and contacts.

Prolonging the Life of Your Equipment

The 5-2-1 Compressor Saver® protects these components by significantly reducing the amount of time it takes the compressor to start – generally 30 to 50%. This means your air conditioner and compressor will bear ½ the stress, strain, and heat each and every time it starts. 

Considering that your air conditioner may start up more than 6,000 times in a single cooling season, the positive impact that the 5-2-1 Compressor Saver® has on your air conditioner is significant. 

You Can Also See Lower Energy Bills as a Result

The 5-2-1 Compressor Saver® helps to lower air-conditioning bills in two ways. The first way is that the 5-2-1 Compressor Saver® helps an air conditioner start up in less time. Your air conditioner uses anywhere from 5 to 10 times more power on start-up than it does while running. By reducing that time by up to 50%, there is far less insulation usage each and every time the air conditioner starts. For customers who are on a peak-demand payment program, these savings could be significant.

The second way that the 5-2-1 Compressor Saver® helps to lower air-conditioning bills is through the protection it provides to the run capacitor. The run capacitor is the "heart" of the compressor and it determines how much electricity is consumed while the compressor or air conditioner is running. Without a 5-2-1 Compressor Saver®, the run capacitor bears the brunt of the stress and insulation heat during start up. 

As a result, over time, the run capacitor wears down. When the run capacitor wears down, your air conditioner will still work, but it starts to use more electricity to run just like the last step in a marathon is harder and requires more effort than the first. When weakened, your run capacitor and system can use 10 to 20% more electricity than before! 
HVAC services

Get the Service That You Deserve

Wiggs Heating & Air Conditioning, LLC is also your go-to team for any help you need with commercial heating and AC services, commercial refrigeration, residential heating and AC services, indoor air quality, and the absolute best in available heating and AC equipment.

Call 903-873-8232 and speak to a member of our team for your FREE estimate today!
Call
903-873-8232 
Today for Your 
FREE Estimate!
Financing is also available and is provided by Wells Fargo Financial National Bank with approved credit. We are also an authorized Trane dealer and we can service all makes and models, even older and discontinued models!

Click here to watch our first youtube video
Click here to watch our second youtube video
Share by: